{"id":16028,"date":"2026-10-08T15:19:17","date_gmt":"2026-10-08T07:19:17","guid":{"rendered":"https:\/\/www.hencolin.com\/?p=16028"},"modified":"2026-10-13T10:49:02","modified_gmt":"2026-10-13T02:49:02","slug":"what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters","status":"publish","type":"post","link":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/","title":{"rendered":"What Percentage of ISO ePM1 Is Equivalent to MERV 13? Don\u2019t Directly Convert Filter Ratings When Purchasing Filters"},"content":{"rendered":"\n<p>When purchasing industrial air filters, specifications may state \u201cMERV 13,\u201d while product information may indicate \u201cISO ePM1.\u201d Since both figures appear to be related to filtration efficiency, can they be directly treated as equivalent?<\/p>\n\n\n\n<p>For procurement and engineering personnel, this is not simply a matter of translating terminology. The real question is whether the proposed product can meet the original specification, required airflow, and HVAC equipment conditions.<\/p>\n\n\n\n<p>Hencolin\u2019s medium-efficiency synthetic-fiber box filter product page provides classification information based on the older EN 779 standard and ASHRAE 52.2. If the project owner has switched to specifying an ePM classification under ISO 16890, suppliers should be asked to provide the corresponding data for the specific model rather than directly converting the MERV value shown on the product page into a particular ePM percentage.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 ez-toc-wrap-left counter-hierarchy ez-toc-counter ez-toc-transparent ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u5927\u7db1<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#Outline\" >Outline<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#What_Percentage_of_ISO_ePM1_Is_Equivalent_to_MERV_13\" >What Percentage of ISO ePM1 Is Equivalent to MERV 13?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#First_Understand_What_the_Two_Classification_Systems_Measure\" >First, Understand What the Two Classification Systems Measure<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#MERV_Performance_Evaluated_by_Particle-Size_Ranges\" >MERV: Performance Evaluated by Particle-Size Ranges<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#ISO_16890_Classification_Using_ePM\" >ISO 16890: Classification Using ePM<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#How_Should_Older_EN_779_Data_Be_Used\" >How Should Older EN 779 Data Be Used?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#When_Comparing_Filter_Ratings_Also_Compare_Airflow_and_Pressure_Drop\" >When Comparing Filter Ratings, Also Compare Airflow and Pressure Drop<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#Five_Items_That_Should_Be_Clearly_Specified_in_Procurement_Documents\" >Five Items That Should Be Clearly Specified in Procurement Documents<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#Frequently_Asked_Questions\" >Frequently Asked Questions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#Can_Online_MERVePM_Comparison_Tables_Not_Be_Used_at_All\" >Can Online MERV\/ePM Comparison Tables Not Be Used at All?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#Is_MERV_13_Necessarily_Better_Than_Every_ePM1_Filter\" >Is MERV 13 Necessarily Better Than Every ePM1 Filter?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#If_the_Efficiency_Rating_Is_Specified_Do_We_Still_Need_to_Consider_Pressure_Drop\" >If the Efficiency Rating Is Specified, Do We Still Need to Consider Pressure Drop?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Outline\"><\/span>Outline<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ul>\n<li>What percentage of ISO ePM1 is equivalent to MERV 13?<\/li>\n\n\n\n<li>First, understand what the two classification systems measure<\/li>\n\n\n\n<li>MERV: Performance evaluated by particle-size ranges<\/li>\n\n\n\n<li>ISO 16890: Classification using ePM<\/li>\n\n\n\n<li>How should older EN 779 data be used?<\/li>\n\n\n\n<li>When comparing filter ratings, also compare airflow and pressure drop<\/li>\n\n\n\n<li>Five items that should be clearly specified in procurement documents<\/li>\n\n\n\n<li>Frequently Asked Questions<\/li>\n\n\n\n<li>Can online MERV\/ePM comparison tables not be used at all?<\/li>\n\n\n\n<li>Is MERV 13 necessarily better than every ePM1 filter?<\/li>\n\n\n\n<li>If the efficiency rating is specified, do we still need to consider pressure drop?<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Percentage_of_ISO_ePM1_Is_Equivalent_to_MERV_13\"><\/span>What Percentage of ISO ePM1 Is Equivalent to MERV 13?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>There is no single fixed conversion value that applies to all filters.<\/p>\n\n\n\n<p>MERV is a classification method based on testing and rating under ASHRAE 52.2, while ISO 16890 classifies filters according to particulate matter removal efficiency, such as ePM1, ePM2.5, and ePM10. The testing and calculation methods used by the two standards are different.<\/p>\n\n\n\n<p>A general comparison table may be useful for preliminary communication, but it cannot replace test results obtained for a specific filter according to the required standard. For formal procurement, compliance should be determined based on the project requirements and the corresponding documentation for the specific product.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"First_Understand_What_the_Two_Classification_Systems_Measure\"><\/span>First, Understand What the Two Classification Systems Measure<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"MERV_Performance_Evaluated_by_Particle-Size_Ranges\"><\/span>MERV: Performance Evaluated by Particle-Size Ranges<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>ASHRAE 52.2 evaluates the particle removal efficiency of general ventilation filters across different particle-size ranges. ASHRAE\u2019s published information divides the relevant ranges into 0.3\u20131.0 \u00b5m, 1.0\u20133.0 \u00b5m, and 3.0\u201310 \u00b5m. The MERV rating is then determined according to the standard test method.<\/p>\n\n\n\n<p>Therefore, MERV is a product classification obtained under a specified test method. It does not mean that a filter removes exactly the same percentage of particles across all particle sizes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"ISO_16890_Classification_Using_ePM\"><\/span>ISO 16890: Classification Using ePM<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>ISO 16890-1 establishes a classification system for air filters used in general ventilation based on particulate matter removal efficiency and specifies requirements for evaluation and labeling.<\/p>\n\n\n\n<p>When a procurement specification states ePM1, ePM2.5, or ePM10, the efficiency percentage following the classification should also be reviewed together with the relevant test documentation. Simply stating \u201ccomplies with ISO 16890\u201d is not sufficient to define the filtration performance required by the project owner.<\/p>\n\n\n\n<p>ISO also notes that laboratory results obtained according to the standard cannot, by themselves, be directly used to quantify or predict filtration efficiency and service life under actual operating conditions. Actual airflow, filter-to-frame sealing, dust loading, and maintenance conditions must also be managed separately.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_Should_Older_EN_779_Data_Be_Used\"><\/span>How Should Older EN 779 Data Be Used?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Existing equipment and some product catalogs may still show classifications such as M5, M6, F7, and F8 under EN 779. These classifications can be useful for identifying historical procurement information or existing product data.<\/p>\n\n\n\n<p>However, if a new project specifically requires ISO 16890 or ASHRAE 52.2, simply replacing the old classification name with a new classification should not be considered sufficient specification verification.<\/p>\n\n\n\n<p>For example, Hencolin\u2019s medium-efficiency synthetic-fiber box filter product page lists various EN 779 and MERV options. However, the product page does not therefore provide an ISO ePM test value for every option.<\/p>\n\n\n\n<p>If the quotation requirement specifies a particular ISO ePM1 efficiency, procurement personnel should provide the complete requirement to Hencolin and ask the supplier to confirm the corresponding model and available documentation.<\/p>\n\n\n\n<p>Do not independently assign an ePM value based on product color, an older classification, or an online comparison table.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"When_Comparing_Filter_Ratings_Also_Compare_Airflow_and_Pressure_Drop\"><\/span>When Comparing Filter Ratings, Also Compare Airflow and Pressure Drop<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Even when two products use the same classification system, it is still necessary to verify whether the product is suitable for the actual AHU.<\/p>\n\n\n\n<p>At a minimum, check:<\/p>\n\n\n\n<ul>\n<li>Actual frame dimensions and filter depth<\/li>\n\n\n\n<li>Rated airflow<\/li>\n\n\n\n<li>Initial pressure drop at the specified airflow<\/li>\n\n\n\n<li>The allowable resistance range of the equipment<\/li>\n<\/ul>\n\n\n\n<p>Hencolin\u2019s box-filter product information lists different dimensions and airflow capacities. When comparing products, these specifications should be matched to the selected model one by one.<\/p>\n\n\n\n<p>The installation method should also not be overlooked. If gaps remain between the filter and the mounting frame, some air may bypass the filter media. Even if the filter media itself meets the required test rating, the actual filtration performance of the system may differ.<\/p>\n\n\n\n<p>Therefore, when requesting a quotation, it is preferable to provide equipment-slot photos, frame configuration, and whether sealing materials are required, and then confirm the final delivery specifications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Five_Items_That_Should_Be_Clearly_Specified_in_Procurement_Documents\"><\/span>Five Items That Should Be Clearly Specified in Procurement Documents<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong>First<\/strong>, specify which standard and classification or efficiency value is required. Avoid using vague descriptions such as \u201chigh efficiency.\u201d<\/p>\n\n\n\n<p><strong>Second<\/strong>, require the quotation to identify the exact corresponding model and confirm that the submitted documentation and delivered product are the same model.<\/p>\n\n\n\n<p><strong>Third<\/strong>, specify the actual dimensions, filter depth, rated airflow, and acceptable initial pressure drop.<\/p>\n\n\n\n<p><strong>Fourth<\/strong>, clearly state the requirements for the mounting frame, flange, and sealing.<\/p>\n\n\n\n<p><strong>Fifth<\/strong>, if the project requires test reports or acceptance documents, confirm the required document contents and delivery method during the quotation stage.<\/p>\n\n\n\n<p>If existing equipment only has EN 779 or MERV records while the new specification uses ePM, procurement personnel can provide both the original filter information and the new project requirements to the supplier.<\/p>\n\n\n\n<p>This allows the supplier to make recommendations based on the airflow and available space of the same equipment, while clearly indicating which performance characteristics are supported by documentation and which still require testing or confirmation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>Frequently Asked Questions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Can_Online_MERVePM_Comparison_Tables_Not_Be_Used_at_All\"><\/span>Can Online MERV\/ePM Comparison Tables Not Be Used at All?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>They can be used for a preliminary understanding of the general relationship between different classification systems. However, they should not be used as the sole proof that a specific product complies with a procurement specification.<\/p>\n\n\n\n<p>Formal evaluation should still be based on the applicable test data for the specific model.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Is_MERV_13_Necessarily_Better_Than_Every_ePM1_Filter\"><\/span>Is MERV 13 Necessarily Better Than Every ePM1 Filter?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>No. First confirm the efficiency percentage following the ePM1 classification, the product\u2019s test method, and the specified airflow. The product can then be evaluated according to the project requirements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"If_the_Efficiency_Rating_Is_Specified_Do_We_Still_Need_to_Consider_Pressure_Drop\"><\/span>If the Efficiency Rating Is Specified, Do We Still Need to Consider Pressure Drop?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Yes. An efficiency classification cannot replace equipment compatibility evaluation. The resistance of the new filter at the design airflow and the actual installation conditions can both affect filter selection.<\/p>\n\n\n\n<p>If your specification includes EN 779, MERV, and ISO ePM classifications at the same time, provide Hencolin with the original filter specification, equipment airflow, filter-slot dimensions, and required test documentation when requesting a quotation.<\/p>\n\n\n\n<p>This will help confirm a suitable medium-efficiency synthetic-fiber box filter or other air-filter product without relying on an assumed direct conversion between different classification systems.&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>When purchasing industrial air filters, specifications may state \u201cMERV 13,\u201d while product information may indicate \u201cISO ePM1.\u201d Since both figures appear to be related to filtration efficiency, can they be directly treated as equivalent? For procurement and engineering personnel, this is not simply a matter of translating terminology. The real question is whether the proposed [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":16021,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_jetpack_memberships_contains_paid_content":false},"categories":[141],"tags":[],"blocksy_meta":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>What Percentage of ISO ePM1 Is Equivalent to MERV 13? Don\u2019t Directly Convert Filter Ratings When Purchasing Filters - Hencolin International |Industrial Air Filter Manufacturer<\/title>\n<meta name=\"description\" content=\"Is MERV 13 equivalent to ISO ePM1? Learn how to compare air filter efficiency, airflow, pressure drop, and test standards for the right HVAC filter.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What Percentage of ISO ePM1 Is Equivalent to MERV 13? Don\u2019t Directly Convert Filter Ratings When Purchasing Filters - Hencolin International |Industrial Air Filter Manufacturer\" \/>\n<meta property=\"og:description\" content=\"Is MERV 13 equivalent to ISO ePM1? Learn how to compare air filter efficiency, airflow, pressure drop, and test standards for the right HVAC filter.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/\" \/>\n<meta property=\"og:site_name\" content=\"Hencolin International\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/hencolin.1990\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-08T07:19:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-13T02:49:02+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hencolin.com\/wp-content\/uploads\/2026\/10\/MERV-13.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1672\" \/>\n\t<meta property=\"og:image:height\" content=\"941\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"doris\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"doris\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/\"},\"author\":{\"name\":\"doris\",\"@id\":\"https:\/\/www.hencolin.com\/en\/#\/schema\/person\/ef72e1b3f81e5d628179a1192fae5bc2\"},\"headline\":\"What Percentage of ISO ePM1 Is Equivalent to MERV 13? Don\u2019t Directly Convert Filter Ratings When Purchasing Filters\",\"datePublished\":\"2026-10-08T07:19:17+00:00\",\"dateModified\":\"2026-10-13T02:49:02+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/\"},\"wordCount\":1222,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/#organization\"},\"articleSection\":[\"Air Filter Articles In Focus\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/\",\"url\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/\",\"name\":\"What Percentage of ISO ePM1 Is Equivalent to MERV 13? Don\u2019t Directly Convert Filter Ratings When Purchasing Filters - Hencolin International |Industrial Air Filter Manufacturer\",\"isPartOf\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/#website\"},\"datePublished\":\"2026-10-08T07:19:17+00:00\",\"dateModified\":\"2026-10-13T02:49:02+00:00\",\"description\":\"Is MERV 13 equivalent to ISO ePM1? Learn how to compare air filter efficiency, airflow, pressure drop, and test standards for the right HVAC filter.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.hencolin.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Air Filter Articles In Focus\",\"item\":\"https:\/\/www.hencolin.com\/en\/category\/air-filter-knowledge-installation-guides-hencolin\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"What Percentage of ISO ePM1 Is Equivalent to MERV 13? Don\u2019t Directly Convert Filter Ratings When Purchasing Filters\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.hencolin.com\/en\/#website\",\"url\":\"https:\/\/www.hencolin.com\/en\/\",\"name\":\"Hencolin \u6f22\u514b\u6797\u4f01\u696d\",\"description\":\"Industrial Air Filter Manufacturer\",\"publisher\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/#organization\"},\"alternateName\":\"Hencolin International\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.hencolin.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.hencolin.com\/en\/#organization\",\"name\":\"Hencolin International\",\"url\":\"https:\/\/www.hencolin.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.hencolin.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/i0.wp.com\/www.hencolin.com\/wp-content\/uploads\/2023\/09\/logo-hencolin.png?fit=253%2C82&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/www.hencolin.com\/wp-content\/uploads\/2023\/09\/logo-hencolin.png?fit=253%2C82&ssl=1\",\"width\":253,\"height\":82,\"caption\":\"Hencolin International\"},\"image\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/hencolin.1990\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.hencolin.com\/en\/#\/schema\/person\/ef72e1b3f81e5d628179a1192fae5bc2\",\"name\":\"doris\",\"url\":\"https:\/\/www.hencolin.com\/en\/author\/doris\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What Percentage of ISO ePM1 Is Equivalent to MERV 13? Don\u2019t Directly Convert Filter Ratings When Purchasing Filters - Hencolin International |Industrial Air Filter Manufacturer","description":"Is MERV 13 equivalent to ISO ePM1? Learn how to compare air filter efficiency, airflow, pressure drop, and test standards for the right HVAC filter.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/","og_locale":"en_US","og_type":"article","og_title":"What Percentage of ISO ePM1 Is Equivalent to MERV 13? Don\u2019t Directly Convert Filter Ratings When Purchasing Filters - Hencolin International |Industrial Air Filter Manufacturer","og_description":"Is MERV 13 equivalent to ISO ePM1? Learn how to compare air filter efficiency, airflow, pressure drop, and test standards for the right HVAC filter.","og_url":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/","og_site_name":"Hencolin International","article_publisher":"https:\/\/www.facebook.com\/hencolin.1990\/","article_published_time":"2026-10-08T07:19:17+00:00","article_modified_time":"2026-10-13T02:49:02+00:00","og_image":[{"width":1672,"height":941,"url":"https:\/\/www.hencolin.com\/wp-content\/uploads\/2026\/10\/MERV-13.jpg","type":"image\/jpeg"}],"author":"doris","twitter_card":"summary_large_image","twitter_misc":{"Written by":"doris","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#article","isPartOf":{"@id":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/"},"author":{"name":"doris","@id":"https:\/\/www.hencolin.com\/en\/#\/schema\/person\/ef72e1b3f81e5d628179a1192fae5bc2"},"headline":"What Percentage of ISO ePM1 Is Equivalent to MERV 13? Don\u2019t Directly Convert Filter Ratings When Purchasing Filters","datePublished":"2026-10-08T07:19:17+00:00","dateModified":"2026-10-13T02:49:02+00:00","mainEntityOfPage":{"@id":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/"},"wordCount":1222,"commentCount":0,"publisher":{"@id":"https:\/\/www.hencolin.com\/en\/#organization"},"articleSection":["Air Filter Articles In Focus"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/","url":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/","name":"What Percentage of ISO ePM1 Is Equivalent to MERV 13? Don\u2019t Directly Convert Filter Ratings When Purchasing Filters - Hencolin International |Industrial Air Filter Manufacturer","isPartOf":{"@id":"https:\/\/www.hencolin.com\/en\/#website"},"datePublished":"2026-10-08T07:19:17+00:00","dateModified":"2026-10-13T02:49:02+00:00","description":"Is MERV 13 equivalent to ISO ePM1? Learn how to compare air filter efficiency, airflow, pressure drop, and test standards for the right HVAC filter.","breadcrumb":{"@id":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/what-percentage-of-iso-epm1-is-equivalent-to-merv-13-dont-directly-convert-filter-ratings-when-purchasing-filters\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.hencolin.com\/en\/"},{"@type":"ListItem","position":2,"name":"Air Filter Articles In Focus","item":"https:\/\/www.hencolin.com\/en\/category\/air-filter-knowledge-installation-guides-hencolin\/"},{"@type":"ListItem","position":3,"name":"What Percentage of ISO ePM1 Is Equivalent to MERV 13? Don\u2019t Directly Convert Filter Ratings When Purchasing Filters"}]},{"@type":"WebSite","@id":"https:\/\/www.hencolin.com\/en\/#website","url":"https:\/\/www.hencolin.com\/en\/","name":"Hencolin \u6f22\u514b\u6797\u4f01\u696d","description":"Industrial Air Filter Manufacturer","publisher":{"@id":"https:\/\/www.hencolin.com\/en\/#organization"},"alternateName":"Hencolin International","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hencolin.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.hencolin.com\/en\/#organization","name":"Hencolin International","url":"https:\/\/www.hencolin.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.hencolin.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/i0.wp.com\/www.hencolin.com\/wp-content\/uploads\/2023\/09\/logo-hencolin.png?fit=253%2C82&ssl=1","contentUrl":"https:\/\/i0.wp.com\/www.hencolin.com\/wp-content\/uploads\/2023\/09\/logo-hencolin.png?fit=253%2C82&ssl=1","width":253,"height":82,"caption":"Hencolin International"},"image":{"@id":"https:\/\/www.hencolin.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/hencolin.1990\/"]},{"@type":"Person","@id":"https:\/\/www.hencolin.com\/en\/#\/schema\/person\/ef72e1b3f81e5d628179a1192fae5bc2","name":"doris","url":"https:\/\/www.hencolin.com\/en\/author\/doris\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/i0.wp.com\/www.hencolin.com\/wp-content\/uploads\/2026\/10\/MERV-13.jpg?fit=1672%2C941&ssl=1","_links":{"self":[{"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/posts\/16028"}],"collection":[{"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/comments?post=16028"}],"version-history":[{"count":3,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/posts\/16028\/revisions"}],"predecessor-version":[{"id":16033,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/posts\/16028\/revisions\/16033"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/media\/16021"}],"wp:attachment":[{"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/media?parent=16028"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/categories?post=16028"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/tags?post=16028"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}