{"id":15667,"date":"2026-06-03T09:10:07","date_gmt":"2026-06-03T01:10:07","guid":{"rendered":"https:\/\/www.hencolin.com\/?p=15667"},"modified":"2026-07-13T16:22:49","modified_gmt":"2026-07-13T08:22:49","slug":"how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance","status":"publish","type":"post","link":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/","title":{"rendered":"How to Install a HEPA High-Efficiency Mini-Pleat Filter? A 4-Step Standard Installation SOP to Ensure Cleanroom Particle Deposition Compliance"},"content":{"rendered":"\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 ez-toc-wrap-left counter-hierarchy ez-toc-counter ez-toc-transparent ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u5927\u7db1<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#How_to_Install_a_HEPA_Mini-Pleat_Filter_A_4-Step_Standard_SOP_to_Ensure_Cleanroom_Compliance\" >How to Install a HEPA Mini-Pleat Filter: A 4-Step Standard SOP to Ensure Cleanroom Compliance<\/a><ul class='ez-toc-list-level-2' ><li class='ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#HEPA_Mini-Pleat_Filter_Installation_SOP\" >HEPA Mini-Pleat Filter Installation SOP<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Step_1_Power_Shutdown_Housing_Cleaning\" >Step 1: Power Shutdown &amp; Housing Cleaning<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Safety_First\" >Safety First<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Clean_the_Installation_Area\" >Clean the Installation Area<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Purpose\" >Purpose<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Step_2_Double-Check_Airflow_Direction\" >Step 2: Double-Check Airflow Direction<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Identify_the_Airflow_Label\" >Identify the Airflow Label<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Align_with_System_Airflow\" >Align with System Airflow<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Purpose-2\" >Purpose<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Step_3_Balanced_and_Precise_Filter_Insertion\" >Step 3: Balanced and Precise Filter Insertion<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Handle_the_Frame_Only\" >Handle the Frame Only<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Insert_Evenly\" >Insert Evenly<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Purpose-3\" >Purpose<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Step_4_Airtightness_Leakage_Inspection\" >Step 4: Airtightness &amp; Leakage Inspection<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Verify_a_Gap-Free_Seal\" >Verify a Gap-Free Seal<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Secure_the_Clamps\" >Secure the Clamps<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Purpose-4\" >Purpose<\/a><\/li><\/ul><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#O_M_Recommendations_and_Differential_Pressure_Management\" >O&amp;M Recommendations and Differential Pressure Management<\/a><ul class='ez-toc-list-level-2' ><li class='ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Establish_the_Initial_Differential_Pressure_Baseline\" >Establish the Initial Differential Pressure Baseline<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Recommended_Replacement_Criteria\" >Recommended Replacement Criteria<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Frequently_Asked_Questions_FAQ\" >Frequently Asked Questions (FAQ)<\/a><ul class='ez-toc-list-level-2' ><li class='ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Q1_What_is_a_Mini-Pleat_design_and_how_does_it_differ_from_traditional_separator-type_HEPA_filters\" >Q1: What is a Mini-Pleat design, and how does it differ from traditional separator-type HEPA filters?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Q2_What_should_I_do_if_I_accidentally_touch_or_puncture_the_filter_media_during_installation\" >Q2: What should I do if I accidentally touch or puncture the filter media during installation?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Q3_What_is_the_installation_difference_between_Gel_Seal_and_Gasket_Seal_mini-pleat_filters\" >Q3: What is the installation difference between Gel Seal and Gasket Seal mini-pleat filters?<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-26\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Gasket_Seal_Filters\" >Gasket Seal Filters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-27\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Gel_Seal_Filters\" >Gel Seal Filters<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-28\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#Technical_Support_Cleanroom_Consultation\" >Technical Support &amp; Cleanroom Consultation<\/a><\/li><\/ul><\/nav><\/div>\n<h1 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_to_Install_a_HEPA_Mini-Pleat_Filter_A_4-Step_Standard_SOP_to_Ensure_Cleanroom_Compliance\"><\/span>How to Install a HEPA Mini-Pleat Filter: A 4-Step Standard SOP to Ensure Cleanroom Compliance<span class=\"ez-toc-section-end\"><\/span><\/h1>\n\n\n\n<p>In high-standard clean environments such as semiconductor manufacturing, microelectronics, biotechnology, pharmaceutical production, and hospital operating rooms, <strong>HEPA Mini-Pleat Filters<\/strong> are commonly used as the final filtration stage in ceiling diffusers or <strong>Fan Filter Units (FFUs)<\/strong>. With filtration efficiency reaching <strong>H14 (99.999%)<\/strong>, they serve as the last line of defense against particulate contamination in critical processes.<\/p>\n\n\n\n<p>Due to their densely pleated structure and delicate filter media, improper handling during installation can easily cause frame deformation, media damage, or seal failure. This guide, prepared by a professional air filtration engineering team, outlines the <strong>four standard installation steps<\/strong> and essential maintenance practices for ensuring optimal performance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"HEPA_Mini-Pleat_Filter_Installation_SOP\"><\/span>HEPA Mini-Pleat Filter Installation SOP<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step_1_Power_Shutdown_Housing_Cleaning\"><\/span>Step 1: Power Shutdown &amp; Housing Cleaning<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Safety_First\"><\/span>Safety First<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Before replacing the filter, switch off the <strong>AHU (Air Handling Unit)<\/strong>, <strong>FFU<\/strong>, or any related ventilation system. Never install or remove a filter while the fan is operating.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Clean_the_Installation_Area\"><\/span>Clean the Installation Area<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Use a cleanroom-grade lint-free wipe and <strong>Isopropyl Alcohol (IPA)<\/strong> to thoroughly clean the filter housing and ceiling grid frame.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Purpose\"><\/span>Purpose<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Maintaining a clean and dry installation area prevents accumulated particles from falling into the cleanroom during replacement and causing secondary contamination.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step_2_Double-Check_Airflow_Direction\"><\/span>Step 2: Double-Check Airflow Direction<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Identify_the_Airflow_Label\"><\/span>Identify the Airflow Label<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Locate the <strong>\u201cAIR FLOW\u201d<\/strong> label and directional arrow on the side of the filter frame.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Align_with_System_Airflow\"><\/span>Align with System Airflow<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Ensure the arrow points in the exact direction of the cleanroom airflow\u2014typically vertically downward or toward the conditioned space.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Purpose-2\"><\/span>Purpose<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Mini-pleat filters are engineered to withstand airflow pressure in a specific direction. Installing the filter backward may result in pleat collapse, media damage, or reduced service life under continuous operating pressure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step_3_Balanced_and_Precise_Filter_Insertion\"><\/span>Step 3: Balanced and Precise Filter Insertion<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Handle_the_Frame_Only\"><\/span>Handle the Frame Only<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Always hold the filter by its outer frame. Never touch, press, or puncture the fragile white pleated filter media with your fingers.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Insert_Evenly\"><\/span>Insert Evenly<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Carefully place the filter into the housing and push it upward (or inward) evenly from both sides until fully seated.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Purpose-3\"><\/span>Purpose<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Uniform force distribution prevents localized stress, frame deformation, and damage to the ultra-fine fiberglass filter media.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step_4_Airtightness_Leakage_Inspection\"><\/span>Step 4: Airtightness &amp; Leakage Inspection<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Verify_a_Gap-Free_Seal\"><\/span>Verify a Gap-Free Seal<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Inspect the perimeter carefully to ensure the filter frame is fully seated against the housing with no visible gaps.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Secure_the_Clamps\"><\/span>Secure the Clamps<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Tighten all retaining clamps or sealing bars evenly around the frame to achieve a complete airtight seal.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Purpose-4\"><\/span>Purpose<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Preventing <strong>bypass leakage<\/strong> is critical. Airborne particles can easily enter the cleanroom through poorly sealed edges. Proper sealing is the most important factor in maintaining the filter&#8217;s <strong>99.999% filtration efficiency<\/strong>.<\/p>\n\n\n\n<h1 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"O_M_Recommendations_and_Differential_Pressure_Management\"><\/span>O&amp;M Recommendations and Differential Pressure Management<span class=\"ez-toc-section-end\"><\/span><\/h1>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Establish_the_Initial_Differential_Pressure_Baseline\"><\/span>Establish the Initial Differential Pressure Baseline<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>After installation and system startup, immediately record the differential pressure reading from the pressure gauge (e.g., a <strong>Magnehelic Differential Pressure Gauge<\/strong>). This value serves as the performance baseline for the new filter.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Recommended_Replacement_Criteria\"><\/span>Recommended Replacement Criteria<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Replace the filter when:<\/p>\n\n\n\n<ul>\n<li>The differential pressure reaches <strong>2 to 2.5 times the initial pressure drop<\/strong> (for example, from an initial 245 Pa to approximately 500\u2013600 Pa); or<\/li>\n\n\n\n<li>The terminal airflow velocity falls below the design specification.<\/li>\n<\/ul>\n\n\n\n<p>Timely replacement helps extend fan motor life and maintain optimal indoor air quality.<\/p>\n\n\n\n<h1 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions_FAQ\"><\/span>Frequently Asked Questions (FAQ)<span class=\"ez-toc-section-end\"><\/span><\/h1>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Q1_What_is_a_Mini-Pleat_design_and_how_does_it_differ_from_traditional_separator-type_HEPA_filters\"><\/span>Q1: What is a Mini-Pleat design, and how does it differ from traditional separator-type HEPA filters?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong>A:<\/strong> Mini-pleat technology uses <strong>hot-melt separators<\/strong> instead of conventional aluminum foil separators to maintain pleat spacing. This design allows more filter media to be packed into the same filter volume, resulting in:<\/p>\n\n\n\n<ul>\n<li>Lower pressure drop<\/li>\n\n\n\n<li>Higher airflow capacity<\/li>\n\n\n\n<li>Reduced weight<\/li>\n\n\n\n<li>Space-saving installation<\/li>\n<\/ul>\n\n\n\n<p>These advantages make mini-pleat filters the preferred choice for modern cleanroom applications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Q2_What_should_I_do_if_I_accidentally_touch_or_puncture_the_filter_media_during_installation\"><\/span>Q2: What should I do if I accidentally touch or puncture the filter media during installation?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong>A:<\/strong> HEPA mini-pleat filters use extremely delicate fiberglass media. Even a small puncture can create microscopic leaks that may not be visible to the naked eye.<\/p>\n\n\n\n<p>It is recommended to:<\/p>\n\n\n\n<ol>\n<li>Suspend use of the damaged filter whenever possible; or<\/li>\n\n\n\n<li>Perform an immediate <strong>PAO aerosol leak test (Scanning Test)<\/strong> after installation.<\/li>\n<\/ol>\n\n\n\n<p>If the leakage rate exceeds <strong>0.01%<\/strong>, the filter must be replaced immediately to prevent contamination of the production environment.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Q3_What_is_the_installation_difference_between_Gel_Seal_and_Gasket_Seal_mini-pleat_filters\"><\/span>Q3: What is the installation difference between Gel Seal and Gasket Seal mini-pleat filters?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Gasket_Seal_Filters\"><\/span>Gasket Seal Filters<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Special attention should be paid to achieving uniform clamp pressure around the perimeter. Uneven tightening may deform the frame and cause air leakage.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Gel_Seal_Filters\"><\/span>Gel Seal Filters<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The knife-edge on the housing must align precisely with the gel-filled channel on the filter. Installation should be performed slowly and vertically to avoid damaging the gel seal and compromising airtightness.<\/p>\n\n\n\n<h1 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Technical_Support_Cleanroom_Consultation\"><\/span>Technical Support &amp; Cleanroom Consultation<span class=\"ez-toc-section-end\"><\/span><\/h1>\n\n\n\n<p>For more information regarding HEPA mini-pleat filter specifications, FFU energy-saving upgrade solutions, or cleanroom air filtration system design, please contact <strong>Hencolin<\/strong> at <strong>+886-8-752-3996<\/strong>. Our professional filtration engineering team is committed to providing reliable and compliant cleanroom solutions tailored to your facility&#8217;s requirements.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>How to Install a HEPA Mini-Pleat Filter: A 4-Step Standard SOP to Ensure Cleanroom Compliance In high-standard clean environments such as semiconductor manufacturing, microelectronics, biotechnology, pharmaceutical production, and hospital operating rooms, HEPA Mini-Pleat Filters are commonly used as the final filtration stage in ceiling diffusers or Fan Filter Units (FFUs). With filtration efficiency reaching H14 [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":15668,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_jetpack_memberships_contains_paid_content":false},"categories":[141,398,381],"tags":[],"blocksy_meta":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How to Install a HEPA High-Efficiency Mini-Pleat Filter? A 4-Step Standard Installation SOP to Ensure Cleanroom Particle Deposition Compliance - Hencolin International |Industrial Air Filter Manufacturer<\/title>\n<meta name=\"description\" content=\"Learn how to properly install HEPA mini-pleat filters with a 4-step SOP. Discover best practices for airflow direction, airtight sealing, differential pressure management, and cleanroom compliance to maximize filtration performance and contamination control.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Install a HEPA High-Efficiency Mini-Pleat Filter? A 4-Step Standard Installation SOP to Ensure Cleanroom Particle Deposition Compliance - Hencolin International |Industrial Air Filter Manufacturer\" \/>\n<meta property=\"og:description\" content=\"Learn how to properly install HEPA mini-pleat filters with a 4-step SOP. Discover best practices for airflow direction, airtight sealing, differential pressure management, and cleanroom compliance to maximize filtration performance and contamination control.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/\" \/>\n<meta property=\"og:site_name\" content=\"Hencolin International\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/hencolin.1990\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-06-03T01:10:07+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-13T08:22:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hencolin.com\/wp-content\/uploads\/2026\/06\/HEPA-Mini-pleat-Filters.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1536\" \/>\n\t<meta property=\"og:image:height\" content=\"1106\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"doris\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"doris\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/\"},\"author\":{\"name\":\"doris\",\"@id\":\"https:\/\/www.hencolin.com\/en\/#\/schema\/person\/ef72e1b3f81e5d628179a1192fae5bc2\"},\"headline\":\"How to Install a HEPA High-Efficiency Mini-Pleat Filter? A 4-Step Standard Installation SOP to Ensure Cleanroom Particle Deposition Compliance\",\"datePublished\":\"2026-06-03T01:10:07+00:00\",\"dateModified\":\"2026-07-13T08:22:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/\"},\"wordCount\":827,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/#organization\"},\"articleSection\":[\"Air Filter Articles In Focus\",\"Air filter installation\",\"Air Filter Knowledge\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/\",\"url\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/\",\"name\":\"How to Install a HEPA High-Efficiency Mini-Pleat Filter? A 4-Step Standard Installation SOP to Ensure Cleanroom Particle Deposition Compliance - Hencolin International |Industrial Air Filter Manufacturer\",\"isPartOf\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/#website\"},\"datePublished\":\"2026-06-03T01:10:07+00:00\",\"dateModified\":\"2026-07-13T08:22:49+00:00\",\"description\":\"Learn how to properly install HEPA mini-pleat filters with a 4-step SOP. Discover best practices for airflow direction, airtight sealing, differential pressure management, and cleanroom compliance to maximize filtration performance and contamination control.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.hencolin.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Air Filter Articles In Focus\",\"item\":\"https:\/\/www.hencolin.com\/en\/category\/air-filter-knowledge-installation-guides-hencolin\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"How to Install a HEPA High-Efficiency Mini-Pleat Filter? A 4-Step Standard Installation SOP to Ensure Cleanroom Particle Deposition Compliance\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.hencolin.com\/en\/#website\",\"url\":\"https:\/\/www.hencolin.com\/en\/\",\"name\":\"Hencolin \u6f22\u514b\u6797\u4f01\u696d\",\"description\":\"Industrial Air Filter Manufacturer\",\"publisher\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/#organization\"},\"alternateName\":\"Hencolin International\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.hencolin.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.hencolin.com\/en\/#organization\",\"name\":\"Hencolin International\",\"url\":\"https:\/\/www.hencolin.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.hencolin.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/i0.wp.com\/www.hencolin.com\/wp-content\/uploads\/2023\/09\/logo-hencolin.png?fit=253%2C82&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/www.hencolin.com\/wp-content\/uploads\/2023\/09\/logo-hencolin.png?fit=253%2C82&ssl=1\",\"width\":253,\"height\":82,\"caption\":\"Hencolin International\"},\"image\":{\"@id\":\"https:\/\/www.hencolin.com\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/hencolin.1990\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.hencolin.com\/en\/#\/schema\/person\/ef72e1b3f81e5d628179a1192fae5bc2\",\"name\":\"doris\",\"url\":\"https:\/\/www.hencolin.com\/en\/author\/doris\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Install a HEPA High-Efficiency Mini-Pleat Filter? A 4-Step Standard Installation SOP to Ensure Cleanroom Particle Deposition Compliance - Hencolin International |Industrial Air Filter Manufacturer","description":"Learn how to properly install HEPA mini-pleat filters with a 4-step SOP. Discover best practices for airflow direction, airtight sealing, differential pressure management, and cleanroom compliance to maximize filtration performance and contamination control.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/","og_locale":"en_US","og_type":"article","og_title":"How to Install a HEPA High-Efficiency Mini-Pleat Filter? A 4-Step Standard Installation SOP to Ensure Cleanroom Particle Deposition Compliance - Hencolin International |Industrial Air Filter Manufacturer","og_description":"Learn how to properly install HEPA mini-pleat filters with a 4-step SOP. Discover best practices for airflow direction, airtight sealing, differential pressure management, and cleanroom compliance to maximize filtration performance and contamination control.","og_url":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/","og_site_name":"Hencolin International","article_publisher":"https:\/\/www.facebook.com\/hencolin.1990\/","article_published_time":"2026-06-03T01:10:07+00:00","article_modified_time":"2026-07-13T08:22:49+00:00","og_image":[{"width":1536,"height":1106,"url":"https:\/\/www.hencolin.com\/wp-content\/uploads\/2026\/06\/HEPA-Mini-pleat-Filters.jpg","type":"image\/jpeg"}],"author":"doris","twitter_card":"summary_large_image","twitter_misc":{"Written by":"doris","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#article","isPartOf":{"@id":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/"},"author":{"name":"doris","@id":"https:\/\/www.hencolin.com\/en\/#\/schema\/person\/ef72e1b3f81e5d628179a1192fae5bc2"},"headline":"How to Install a HEPA High-Efficiency Mini-Pleat Filter? A 4-Step Standard Installation SOP to Ensure Cleanroom Particle Deposition Compliance","datePublished":"2026-06-03T01:10:07+00:00","dateModified":"2026-07-13T08:22:49+00:00","mainEntityOfPage":{"@id":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/"},"wordCount":827,"commentCount":0,"publisher":{"@id":"https:\/\/www.hencolin.com\/en\/#organization"},"articleSection":["Air Filter Articles In Focus","Air filter installation","Air Filter Knowledge"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/","url":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/","name":"How to Install a HEPA High-Efficiency Mini-Pleat Filter? A 4-Step Standard Installation SOP to Ensure Cleanroom Particle Deposition Compliance - Hencolin International |Industrial Air Filter Manufacturer","isPartOf":{"@id":"https:\/\/www.hencolin.com\/en\/#website"},"datePublished":"2026-06-03T01:10:07+00:00","dateModified":"2026-07-13T08:22:49+00:00","description":"Learn how to properly install HEPA mini-pleat filters with a 4-step SOP. Discover best practices for airflow direction, airtight sealing, differential pressure management, and cleanroom compliance to maximize filtration performance and contamination control.","breadcrumb":{"@id":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.hencolin.com\/en\/air-filter-knowledge-installation-guides-hencolin\/how-to-install-a-hepa-high-efficiency-mini-pleat-filter-a-4-step-standard-installation-sop-to-ensure-cleanroom-particle-deposition-compliance\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.hencolin.com\/en\/"},{"@type":"ListItem","position":2,"name":"Air Filter Articles In Focus","item":"https:\/\/www.hencolin.com\/en\/category\/air-filter-knowledge-installation-guides-hencolin\/"},{"@type":"ListItem","position":3,"name":"How to Install a HEPA High-Efficiency Mini-Pleat Filter? A 4-Step Standard Installation SOP to Ensure Cleanroom Particle Deposition Compliance"}]},{"@type":"WebSite","@id":"https:\/\/www.hencolin.com\/en\/#website","url":"https:\/\/www.hencolin.com\/en\/","name":"Hencolin \u6f22\u514b\u6797\u4f01\u696d","description":"Industrial Air Filter Manufacturer","publisher":{"@id":"https:\/\/www.hencolin.com\/en\/#organization"},"alternateName":"Hencolin International","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hencolin.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.hencolin.com\/en\/#organization","name":"Hencolin International","url":"https:\/\/www.hencolin.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.hencolin.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/i0.wp.com\/www.hencolin.com\/wp-content\/uploads\/2023\/09\/logo-hencolin.png?fit=253%2C82&ssl=1","contentUrl":"https:\/\/i0.wp.com\/www.hencolin.com\/wp-content\/uploads\/2023\/09\/logo-hencolin.png?fit=253%2C82&ssl=1","width":253,"height":82,"caption":"Hencolin International"},"image":{"@id":"https:\/\/www.hencolin.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/hencolin.1990\/"]},{"@type":"Person","@id":"https:\/\/www.hencolin.com\/en\/#\/schema\/person\/ef72e1b3f81e5d628179a1192fae5bc2","name":"doris","url":"https:\/\/www.hencolin.com\/en\/author\/doris\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/i0.wp.com\/www.hencolin.com\/wp-content\/uploads\/2026\/06\/HEPA-Mini-pleat-Filters.jpg?fit=1536%2C1106&ssl=1","_links":{"self":[{"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/posts\/15667"}],"collection":[{"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/comments?post=15667"}],"version-history":[{"count":1,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/posts\/15667\/revisions"}],"predecessor-version":[{"id":15670,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/posts\/15667\/revisions\/15670"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/media\/15668"}],"wp:attachment":[{"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/media?parent=15667"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/categories?post=15667"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hencolin.com\/en\/wp-json\/wp\/v2\/tags?post=15667"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}